Please use this identifier to cite or link to this item:https://hdl.handle.net/20.500.12259/90598
Type of publication: Straipsnis mokslo-populiarinimo leidinyje / Article in popular science editions (S6)
Field of Science: Aplinkos inžinerija / Environmental engineering (T004)
Author(s): Šarapnickis, Paulius;Venslauskas, Kęstutis
Title: Statybinių medienos atliekų utilizavimas
Other Title: Disposal of construction wood waste
Is part of: Agroinžinerija ir energetika : ASU Žemės ūkio inžinerijos fakulteto mokslo populiarinimo ir gamybos žurnalas. , 2017, Nr. 22
Extent: p. 52-55
Date: 2017
Keywords: Construction wood;Wood waste disposal;Recovered demolition fuel;Burning const-ruction wood waste;Flue gas of burning construction wood waste
Abstract: Eksperimentinis tyrimas buvo atliktas 2016-2017 metu laikotarpiu Energetikos ir biotechnologijų inžinerijos institute naudojant vamzdinės krosnies stendą RS 80/500/11 ir išmetamųjų dujų analizatorių TESTO 350. Mokslinio tyrimo objektas buvo statybinė ir griovimo mediena (mediena dažyta vandens pagrindo dažais, natūrali spygliuočių mediena, mediena 48 valandas mirkyta betono mišinyje ir 30 metų senumo mediena su kalkinio tinko likučiais). Sudeginus dažytą medieną buvo pastebėta jog SO2 koncentracija pasiekia66 mg/m3 po 105 s nuo degimo pradžios, kai kitų medienos rūšių SO2 koncentracijos buvo 2 ar net 3 kartus mažesnės. Taip pat buvo atliktas drėgnio ir peleningumo tyrimas. Tiriamų mėginių drėgnio kiekis svyravo nuo 3,3 % iki 5,6 %, o peleningumas nuo 0,5 % iki 30,8%
Experimental trials were carried out in 2016-2017 at Institute of energy and biotechnolo-gy engineering using tube furnance stand RS 80/500/11 and flue gas analyser TESTO 350. The objects of research were construction and demolition wood (wood painted water based white paints, natural conifer wood, wood soaked for 48 h in concrete and 30 years old plastered wood). After burning painted wood it was obtained that highest SO2 concentration was 66 mg/m3 after 105 s of beginning burning. In other wood flue gas emissions were 2 or 3 times lower. Also there were made research of ash and humidity. On research facilities moisture content ranged from 3,3 % to 5,6 % and ash content from 0,5 % to 30,8%
Internet: https://hdl.handle.net/20.500.12259/90598
Affiliation(s): Vytauto Didžiojo universitetas
Žemės ūkio akademija
Appears in Collections:Universiteto mokslo publikacijos / University Research Publications

Files in This Item:
marc.xml5.89 kBXMLView/Open

MARC21 XML metadata

Show full item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats


CORE Recommender

Page view(s)

74
checked on Dec 10, 2020

Download(s)

14
checked on Dec 10, 2020

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.