Title: Švino-sieros rūgšties baterijų vidinės varžos tyrimas
Is part of: Agroinžinerija ir energetika: ASU Žemės ūkio inžinerijos fakulteto mokslo populiarinimo ir gamybos žurnalas. , 2013, Nr. 18
Extent: p. 82-85
Date: 2013
Abstract: Practical tests were made with lead acid battery GPL12120, which has 12 Ah capacity and 12 V voltage per unit. Battery internal resistance was analysed using voltage drop method. It is estimated that battery internal resistance at discharge characteristic was stable about 42 mQ, from Hk to 50 % state of charge. At the end of discharge process internal resistance rises to 725 is climated that internal resistance at all charge process increased from 75 mQ to 2,5 £2