Type of publication: Straipsnis konferencijos medžiagoje kitose duomenų bazėse / Article in conference proceedings in other databases (P1c)
Field of Science: Aplinkos inžinerija / Environmental engineering (T004)
Author(s): Aškinis, Simonas
Title: Treatment of wastewater in milk collecting station
Is part of: Research for rural development 2006 : International scientific conference proceedings : Jelgava, Latvia, 17-20 May, 2006. Jelgava : Latvia University of Agriculture, 2006
Extent: p. 106–112
Date: 2006
Keywords: Primary treatment of wastewater;Quicklime;Coagulants;Constructed wetlands;Treatment efficiency
ISBN: 9984784142
Abstract: The paper presents the results of studies on the treatment of wastewater in experimental treatment facilities in a milk collecting station The treatment process of wastewater was as follows: aeration-flocculation device - sedimentation pond - two-stage constructed wetlands. The laboratory investigations have shown that the primary treatment with quicklime (1 kg m"3) reduces wastewater pollution by 54%, while the treatment with coagulant 7ETAG 8660' (4 g m"3) reduces it by even 68%. Such results were not obtained in the primary wastewater treatment stage under industrial conditions: biological oxygen demand (BOD5) in wastewater was reduced 27.2%, the amount of suspended sediment was reduced by 48.1%, the amounts of N,total and Ptotal decreased by 15.8% and 27% respectively. Such results much depended on the air temperature, inaccurate dosage of chemicals as well as on insufficient capacity of reaction and sedimentation reservoirs for 2.5 times higher amount of wastewater. However, despite such unfavourable conditions, this stage of treatment process was rather efficient: the pollution of wastewater with organic matter flowing into the stream did not exceed the maximum allowable rates. The average value according to BOD; was 4 mg 02l-1, the highest BOD; value was 9.6 mg 0,1"'. From the environment protection point of view, it is particularly important that the removal of biogenic pollutants is quite sufficient in the wastewater treatment facilities. After the treatment process in wastewater treatment facilities, the amount of Ntotal decreased by 82.4%, and the amount of Ptotal was reduced by even 97.3%
Internet: https://hdl.handle.net/20.500.12259/85395
Affiliation(s): Vytauto Didžiojo universitetas
Žemės ūkio akademija
Appears in Collections:Universiteto mokslo publikacijos / University Research Publications

Files in This Item:
marc.xml6.14 kBXMLView/Open

MARC21 XML metadata

Show full item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats


CORE Recommender

Page view(s)

48
checked on Sep 7, 2020

Download(s)

12
checked on Sep 7, 2020

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.