Author(s): Ambrulevičius, Rimvydas
Title: Šilumos nuostolių mažinimas saulės kolektoriuose
Other Title: Heat loss reduction in sun collectors
Is part of: Žemės ūkio inžinerija. , [T.] 38, Nr. 1 (2006)
Extent: p. 66-74
Date: 2006
Keywords: Kolektorius;Šiluma;Oras;Nuostoliai;Temperatūra;Collectors;Heat;Air;Losses;Temperature
Abstract: Straipsnyje nagrinėjamos oro šildymo kolektorių naudingumo padidinimo ir šilumos nuostolių mažinimo galimybės pašildant orą iki didesnės temperatūros. Sukurtas ir išbandytas naujos konstrukcijos kolektorius. Konstrukciniu atžvilgiu tai dviejų eigų kolektorius, kuriame oras pašildomas keliais etapais. Tai leidžia sumažinti nuostolius ir padidinti naudingumo koeficientą iki 0,71. Konstrukcija pasižymi nedideliais slėgio nuostoliais. Todėl ventiliavimui gali būti naudojami standartiniai ventiliatoriai. Maksimali pašildomo oro temperatūra 63 oC, kai naudingumo koeficientas – 0,58. Maksimali kolektoriaus galia 750 W/m2 absorberio ploto. Šie parametrai pasiekti esant dvipusiam absorberio apgaubimui pašildomu oru. Naudojant tokios konstrukcijos kolektorius rekuperacinėse sistemose reikia taikyti oro srautų perskirstymą. Priešingu atveju kolektoriaus naudingumo koeficientas sumažėja iki 0,32-0,38
The possibilities of increasing efficiency of air heating collectors and reduction heat loss while heating air up to higher temperature are analyzed in the article. The new construction collector was created and tested. In construction point of view it is two-motion collector, in which air is heated in several steps. This enables to reduce losses and increase efficiency coefficient up to 0.71. One of characteristic feature of this construction is small losses. Therefore standard ventilators could be used for heating. Maximal temperature of heated air is 63 oC, when efficiency coefficient is 0.58. Maximal collector power is 750 W/m2 of absorber width. These parameters were reached, when absorber was surrounded by heated air from both sides. Using collectors of such construction in recuperative systems, the airflow distribution should be applied. If not, the efficiency coefficient of collector reduces up to 0.32-0.38
Internet: https://hdl.handle.net/20.500.12259/85161
Affiliation(s): Vytauto Didžiojo universitetas
Žemės ūkio akademija
Appears in Collections:Universiteto mokslo publikacijos / University Research Publications

Files in This Item:
marc.xml6.73 kBXMLView/Open

MARC21 XML metadata

Show full item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats


CORE Recommender

Page view(s)

36
checked on Dec 11, 2019

Download(s)

6
checked on Dec 11, 2019

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.