Asinchroninės mašinos su faziniu rotoriumi darbo generatoriaus režimu tyrimas
Date |
---|
2012 |
This paper investigated the operation of asynchronous generator with phase rotor, feeding the stator and rotor phase windings with DC. Electromagnetic processes, which are taking place while feeding the stator and rotor windings with DC were theoretically discussed. Studies have shown that increased load current If = 4,2 A and load power P2 = 1685 W are achieved by feeding the stator winding with DC. Research has shown that greater asynchronous generator efficiency ηG = 0,898 was reached when feeding the rotor winding with DC, but due to flawed asynchronous generator design this ratio began to decline past mentioned limit. In this research the maximum load current was If = 2,92 A and load capacity P2 = 862,5 W. Inducing the stator winding by DC, seemingly higher asynchronous generator energy indicators are achieved.