Please use this identifier to cite or link to this item:https://hdl.handle.net/20.500.12259/84312
Type of publication: research article
Field of Science: Mechanikos inžinerija / Mechanical Engineering (T009)
Author(s): Pupelis, Žilvinas;Laurinėnas, Alvydas
Title: Elektros instaliacijos ilgalaikio eksploatavimo įtaka gaisrų rizikai
Other Title: Electrical wiring long-term impact of running the risk of fire
Is part of: Žmogaus ir gamtos sauga 2012 : 18 tarptautinės mokslinės-praktinės konferencijos medžiaga = Human and nature safety 2012 : proceedings of the international scientific conference. Akademija (Kauno r.), 2012, D. 1
Extent: p. 36-38
Date: 2012
Keywords: Gaisras;Rizika;Instaliacija;Izoliacija;Degimas;Fire;Risk;Wiring;Insulation;Combustion
Abstract: Kas dešimto gaisro priežastimi yra netvarkingos elektros įrangos ir instaliacijos eksploatavimas. Dėl ilgalaikio pastatų ir statinių elektros instaliacijos eksploatavimo prastėja jos dielektrinės savybės, mechaninis ir šiluminis atsparumas elektros antsrovių ir viršįtampių poveikiui. Izoliacinės laidų ir kabelių dangos dažniau užsidega, o ugnis plinta sparčiau, tampa uždegimo šaltiniu. Tirtos skirtingų izoliacinių medžiagų laidų ir kabelių degumo savybės, ugnies plitimo greičio požiūriu. Gauta, kad ilgalaikio eksploatavimo nerenovuotos pastato elektros instaliacijos gaisro rizika yra 3 – 4 kartus didesnė
Between 2007 - 2011 period, electrical equipment and wiring faults caused fires accounted for about 11%. Among the causes of electrical fires caused most commonly mentioned: short circuits and leakage currents of 41% of the electrical supply, wiring aging 14%, and external and internal surges 6%. Longer than 15 years of operation of wire and cable transmission rate of combustion is higher by 17.9% - plastic insulation and 113% - rubber. Refractory caleb rate almost two times lower (49.2%) than the conventional insulation of cables and wires. To reduce the wiring caused the fire risk is appropriate for more than 10-15 years old, operated on the electrical network at least 15-20% reduction in power loads. It is found that long-term operation of renovated building wiring fire risk is 3-4 times higher
Internet: https://hdl.handle.net/20.500.12259/84312
Affiliation(s): Vytauto Didžiojo universitetas
Žemės ūkio akademija
Appears in Collections:Universiteto mokslo publikacijos / University Research Publications

Files in This Item:
marc.xml6.37 kBXMLView/Open

MARC21 XML metadata

Show full item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats


CORE Recommender

Page view(s)

34
checked on Dec 11, 2019

Download(s)

6
checked on Dec 11, 2019

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.