Please use this identifier to cite or link to this item:https://hdl.handle.net/20.500.12259/82337
Type of publication: research article
Type of publication (PDB): Straipsnis kitose duomenų bazėse / Article in other databases (S4)
Field of Science: Energetika ir termoinžinerija / Energetics and thermal engineering (T006)
Author(s): Kavolynas, Antanas;Šateikis, Ignas;Navickas, Kęstutis
Title: Šilumnešio debito įtakos vakuuminio saulės kolektoriaus energetinėms charakteristikoms tyrimas
Other Title: Research on influence of heat-transfer debit to energy characteristic of evacuateds tubes heat-pipe solar collector
Is part of: Žemės ūkio inžinerija. , Nr. 41(3-4) (2009)
Extent: p. 5-17
Date: 2009
Keywords: Vakuuminis saulės kolektorius;Šilumos vamzdis;Naudingumo koeficientas;Saulės imitatorius;Evacuated tubes solar collector;Heat-pipe;Coeficient of efficiency;Solar indicator
Abstract: Eksperimentiškai tirtas vakuuminis saulės kolektorius, kuriame šiluminei energijai /esti įrengtas uždaras šilumos vamzdis. Laboratoriniai tyrimai atlikti naudojant saulės tatorių, kuris sudarė 800 W/m2 energinę apšvietą, ir apipučiant kolektorių 2 m/s oro utu. Tirtos saulės kolektoriaus energetinės charakteristikos keičiant šilumnešio debitą, alės kolektoriaus naudingumo koeficiento priklausomybės nuo šilumnešio debito larytos esant pastovioms sąlygoms. Nustatyta, kad naudojant didesnį debitą (0,118 kg/s) idingumo koeficientas siekė 0,58. Naudojant mažesnį debitą (0,011 kg/s) naudingumo eficientas gautas didesnis (0,82). Nustatyta, kad vakuuminio saulės kolektoriaus 3rgetinėms charakteristikoms didžiausios įtakos turėjo šilumos nuvedimo faktorius, kuris psniškai priklauso nuo šilumnešio debito
Tie evacuated tubes solar collector with a close heat-pipe was researched tperiments. The laboratory tests were performed using a solar simulator .nergy lighting of 800 W/m2, and blowing a 2 m/s air flow on the ["he energy characteristics of the solar collector were researched when the debit of the heat-carrier. The dependence of the coefficient of n the heat-transfer debit were performed under permanent conditions. It ined that when a bigger debit (0.118 kg/s) was used, the coefficient of reached 0.58, while with a smaller debit (0.011 kg/s) the coefficient of was bigger (0.82). It was also determined that the energy characteristics ated tubes of the solar collector were mostly influenced by the heat off-. which is correspondingly dependent on the heat-carrier
Internet: https://hdl.handle.net/20.500.12259/82337
Affiliation(s): Vytauto Didžiojo universitetas
Žemės ūkio akademija
Appears in Collections:Universiteto mokslo publikacijos / University Research Publications

Files in This Item:
marc.xml7.28 kBXMLView/Open

MARC21 XML metadata

Show full item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats


CORE Recommender

Page view(s)

13
checked on Mar 30, 2021

Download(s)

7
checked on Mar 31, 2021

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.