Please use this identifier to cite or link to this item:https://hdl.handle.net/20.500.12259/82160
Type of publication: conference paper
Type of publication (PDB): Straipsnis nerecenzuojamoje Lietuvos konferencijos medžiagoje / Article in non-peer-reviewed Lithuanian conference proceedings (P2c)
Field of Science: Energetika ir termoinžinerija / Energetics and thermal engineering (T006)
Author(s): Kavolynas, Antanas
Title: Vakuuminio saulės kolektoriaus karštam vandeniui ruošti energetinių charakteristikų tyrimas
Other Title: Research on power characteristics of vacuum solar collector to heat water
Is part of: Jaunimas siekia pažangos - 2009 / LŽŪU. , 2009
Extent: p. 165-168
Date: 2009
Keywords: Vakuuminis saulės kolektorius;Tyrimo stendas;Energinė apšvieta;Naudingumo koeficientas;Evacuated tubes solar collector;Research stand;Solar imitator;Coeficient of efficiency
Abstract: Eksperimentiškai tirtas vakuuminis saulės kolektorius. Tyrimai atlikti laboratoriniame saulės kolektorius tyrimo stende, kuris sudarytas iš vakuuminio saulės kolektoriaus, cirkuliacinio siurblio akumuliacinės talpyklos bei matavimo įrangos. Saulės kolektoriaus energetinės charakteristikos tirtos naudojant saulės imitatorių, kuris sudarė 400, 600, 800, 1000 W/m2 energinę apšvietą, bei apipučiant kolektorių 3 m/s oro srautu. Tyrimai atlikti naudojant uždaro srauto sistemą ir esant pastoviam šilumnešio debitui. Sudarytos saulės kolektoriaus naudingumo koeficiento priklausomybės, esant skirtingoms energinėms apšvietoms. Nustatyta, kad energinės apšvietos dydis turi įtakos vakuuminio saulės kolektoriaus energetinėms charakteristikoms
Experimental research was performed on a evacuated tubes solar collector. The research was performed on a laboratory solar collector stand, which consists of a solar collector, an accumulative container of the circulating pump and measuring equipment. The power characteristics of the solar collector were researched by using a solar imitator which created irradiance of 400. 600, 800, 1000 W/m2, and spraying the collector with 3 m/s air flow. The research was performed using a close-flow system at a constant heat-carrier fluid flow rate. Dependences of the coefficient of efficiency of the solar collector were established using different irradiance. It was determined that the amount of irradiance influences the power characteristics of the solar collector
Internet: https://hdl.handle.net/20.500.12259/82160
Affiliation(s): Vytauto Didžiojo universitetas
Žemės ūkio akademija
Appears in Collections:Universiteto mokslo publikacijos / University Research Publications

Files in This Item:
marc.xml5.91 kBXMLView/Open

MARC21 XML metadata

Show full item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats


CORE Recommender

Page view(s)

11
checked on Mar 30, 2021

Download(s)

7
checked on Mar 31, 2021

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.