Please use this identifier to cite or link to this item:https://hdl.handle.net/20.500.12259/59712
Type of publication: conference paper
Type of publication (PDB): Tezės kituose recenzuojamuose leidiniuose / Theses in other peer-reviewed publications (T1e)
Field of Science: Biologija / Biology (N010)
Author(s): Dūda, Gediminas;Drevinskas, Tomas;Maruška, Audrius
Title: Updates of development and integration of miniaturized capillary electrophoresis equipment into unmanned aerial vehicle for analysis of complex mixtures (DRONOMOUS)
Is part of: The vital nature sign [electronic resource] : 12th international scientific conference, May 17-18, 2018, Kaunas, Lithuania : abstract book / editors Nicola Tiso, Vilma Kaškonienė. Kaunas : Vytautas Magnus university, 2018, [no. 12]
Extent: p. 36-36
Date: 2018
Note: Online ISSN: 2335-8718. This project was financed by Research Council of Lithuania project No. 09.3.3-LMT-K-712-03-0130
Keywords: Capillary electrophoresis;Contactless conductivity detector;Gas – liquid extraction;Environment
Abstract: Capillary electrophoresis is powerful technique for separating chemical compounds in aqueous solutions. The aim of this study is develop fully automated miniaturized capillary electrophoresis equipment for chemical analysis of air samples. Integration into unmanned aerial vehicle allows to conduct air chemical analysis on spot, without need to manually collect samples. Successful integration of capillary electrophoresis into unmanned aerial vehicle will widen possibilities of environment research. Analysis system consist of two major parts. First part is automated air sample collection and extraction system, based upon gas – liquid extraction method, using 10 mM acetic acid buffer as extraction solvent. Second part is fully automated capillary electrophoresis system. Air sample extraction conditions: 50 μl of 10 mM acetic acid buffer was used as extraction solvent, extraction was conducted for 30 minutes. After extraction process, extracts are analyzed using capillary electrophoresis method. Analysis conditions are: 0.5 M acetic acids is used as background electrolyte, 50 μm inner diameter fussed silica capillary (total length - 30 cm, length to the detector – 22 cm), sample injection – hydrodynamic 50 kPa *30 s, analysis voltage 4 kV, analysis time - 9 minutes, detector type – contactless conductivity detector. Analysis results shows that miniaturized and fully automated capillary electrophoresis equipment coupled with gas – liquid extraction system is capable of conducting high effectiveness air chemical analysis
Internet: http://vns.microsep.org/wp-content/uploads/2018/05/AbstractbookVNS2018.pdf
Affiliation(s): Biologijos katedra
Gamtos mokslų fakultetas
Vytauto Didžiojo universitetas
Appears in Collections:Universiteto mokslo publikacijos / University Research Publications

Files in This Item:
marc.xml7.05 kBXMLView/Open

MARC21 XML metadata

Show full item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats


CORE Recommender

Page view(s)

20
checked on Mar 30, 2021

Download(s)

9
checked on Mar 31, 2021

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.