Please use this identifier to cite or link to this item:https://hdl.handle.net/20.500.12259/112455
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorKavolynas, Antanas-
dc.contributor.authorOlensevičius, Tadas-
dc.date.accessioned2020-12-21T19:03:20Z-
dc.date.available2020-12-21T19:03:20Z-
dc.date.issued2016-04-25-
dc.identifier.urihttps://hdl.handle.net/20.500.12259/112455-
dc.description.abstractDarbe apžvelgiamos galimybės naudoti saulės kolektorius Lietuvoje, taip pat saulės energijos potencialas Lietuvoje. Apžvelgiamos saulės kolektorių sistemų rūšys karštam vandeniui ruošti. Tyrimo tikslas - ištirti vakuuminio saulės kolektoriaus sistemos energetines charakteristikas sistemoje keičiant šilumnešio debitą. Eksperimentiniai saulės kolektoriaus sistemos tyrimai atlikti laboratorijoje naudojant saulės energinės apšvietos imitatorių. Imitatoriumi sukurta 1000 W/m2 energinė apšvieta. Saulės kolektoriaus sistemos tyrimo stendą sudaro: vakuuminis saulės kolektorius, akumuliacinė talpa, cirkuliacinis siurblys, matavimo įranga. Nustatytos saulės kolektoriaus sistemos energetinių charakteristikų priklausomybės nuo šilumnešio debito. Tyrimo metu ant saulės kolektoriaus pateko 8,6 kWh šilumos energijos. Esant mažiausiam debitui (0,01 kg/(s•m2)) kolektoriaus konvertuota šilumos energija buvo 7,64 kWh iš kurių 3,24 kWh buvo šiluminės energijos nuostoliai. Sistemoje naudojant didžiausią šilumnešio debitą (0,12 kg/(s•m2)) kolektoriaus konvertuota šilumos energija buvo 5,14 kWh iš kurių 0,96 kWh buvo šiluminės energijos nuostoliai. Akumuliacinėje talpykloje sukauptas šilumos energijos kiekis kito mažai (4,18–4,69 kWh).lt
dc.description.abstractThe paper has analysed possibilities of solar collectors usage in Lithuania. Where was also analysed solar irradiance in Lithuania. Reviewed types of solar collector systems for water heating. The main task of the research is to analyse solar collector system energy characteristics with different heat-carrier flow rate. Experimental researches have been performed in the laboratory using solar collector system stand. There was 1000 W/m2 made by solar irradiance simulator. Experimental solar collector stand have main parts: evacuated tubes solar collector, accumulative capacity, circulation pump, measuring equipment. Was found solar collector system energy characteristics dependence of heat-carrier flow rate. There was 8.6 kWh given from solar irradiance simulator to evacuated tubes solar collector. Then heat-carrier flow rate was low (0.01 kg/(s•m2)) solar collector converted heat energy was high (7.64 kWh). But it was also high heat energy losses (3.24 kWh). Then heat-carrier flow rate was high (0.12 kg/(s•m2)) solar collector converted heat energy was low (5.14 kWh) and heat energy losses was low (0.96 kWh). Heat energy accumulated in accumulative capacity was changed slightly from 4.18 kWh to 4.69 kWh in different heat-carrier flow rate.en
dc.description.sponsorshipŽemės ūkio akademijalt
dc.description.sponsorshipVytauto Didžiojo universitetaslt
dc.format.extent54 p.-
dc.language.isolt-
dc.subjectsaulėlt
dc.subjectenergijalt
dc.subjectkolektoriuslt
dc.subjectsolaren
dc.subjectenergyen
dc.subjectcollectoren
dc.subject.otherEnergetika ir termoinžinerija / Energetics and thermal engineering (T006)-
dc.titleSaulės kolektoriaus sistemos tyrimaslt
dc.title.alternativeResearch of Solar Collector Systemen
dc.typemaster thesis-
item.grantfulltextopen-
item.fulltextWith Fulltext-
crisitem.author.deptŽemės ūkio akademija-
crisitem.author.deptŽemės ūkio inžinerijos fakultetas-
Appears in Collections:VDU, ASU ir LEU iki / until 2018
Files in This Item:
Show simple item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats


CORE Recommender

Page view(s)

5
checked on May 1, 2021

Download(s)

3
checked on May 1, 2021

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.