Author(s): Laurinėnas, Alvydas
Title: Mokymo kalvės apšvietimo tyrimas
Other Title: Researchs of illumination in training forge
Is part of: Žmogaus ir gamtos sauga 2014 : 20 tarptautinės mokslinės-praktinės konferencijos medžiaga = Human and nature safety 2014 : proceedings of the 20th international scientific-practice conference / Aleksandro Stulginskio universitetas, Vytauto Didžiojo universitetas, Lietuvos mokslų akademija. Akademija, 2014, D. 1
Extent: p. 42-44
Date: 2014
Keywords: Mokomoji kalvė;Apšvietimas;Natūralus;Dirbtinis;Training forge;Daylight;Artificial illumination
Abstract: Straipsnyje pateikiama mokymo kalvės apšvietimo tyrimo rezultatai. Natūralaus apšvietimo natūralios apšvietos koeficientas (NAK) kalvėje 1 m atstume nuo galinės patalpos sienos siekė apie 0,2 %. Dirbtinio bendrojo apšvietimo vidutinė apšvieta patalpoje buvo 41 lx. Priekalo vietinio apšvietimo vidutinė apšvieta siekė 14 lx, o kombinuota apie 60 lx. Vulkanizavimo darbų vietos kombinuota apšvieta siekė 93 lx, o vietinė apšvieta suvirinimo darbų kabinose apie 28 lx. Litavimo darbastaliai apšviečiami kombinuota 97 lx apšvieta. Natūrali ir dirbtinė apšvieta mokymo kalvėje yra nepakankama, nes pagal Lietuvos higienos normą HN 98:2000 dirbtinė apšvieta turi būti ne mažesnė kaip 200 lx, o natūralaus apšvietimo koeficientas 1,1% vertės. Pagal standartus LST EN 12464 bei ISO 8995 apšvietos lygis turi būti ne mažesnis kaip 300 lx. Mokymo kalvės apšvietimas yra nepakankamas ir apšvietimo sistemą reikia normalizuoti
This article analyzes the problematic of illumination in the training forge . Coefficient of daylight-illumination in this premise (0,2 %) was found at the distance of 1 m from back wall. Average artificial illumination in premise was 41 lx, while the workplace was locally illuminated by 14 lx and combined illumination was 60 lx. Combined illumination in the workplace of vulcanization was 93 lx, while 28 lx in welding rooms respectively. Illumination of 97 lx in solder workplaces was found respectively. Daylight and artificial illumination in forge is unsatisfactory yet in reference to Lithuanian hygiene norm HN 98:2000 artificial illumination should not be less than 200 lx and coefficient of illumination 1,1 %. According to the requirements of the standards LST EN 12464 and ISO 8995 sufficient illumination for such premises should be ≥300 lx. Illumination in forge should be normalized
Internet: https://hdl.handle.net/20.500.12259/86949
Affiliation(s): Vytauto Didžiojo universitetas
Žemės ūkio akademija
Appears in Collections:Universiteto mokslo publikacijos / University Research Publications

Files in This Item:
marc.xml6.29 kBXMLView/Open

MARC21 XML metadata

Show full item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats


CORE Recommender

Page view(s)

54
checked on Dec 10, 2020

Download(s)

14
checked on Dec 10, 2020

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.