Title: Kieto kuro šildymo katilų valdymo tyrimas
Other Title: Investigating Operation Control of Solid Fuel Fired Boilers
Extent: 53 p.
Date: 22-May-2012
Keywords: kieto kuro katilas;dujų generacijos katilas;biokuras;automatinis valdymas;wood fuel;biofuel;solid fuel boiler;lambda sensor
Abstract: Norėdami kuo efektyviau naudoti biokurą, siekiame, kad kuo efektyviau būtų sudeginamas kuras kieto kuro katiluose, patobulinus kieto kuro degimo procesą. Šiame darbe nagrinėjama galimybė papildomo ventiliatoriaus pagalba keisti dūmų sudėtį įjungus į valdymo grandinę ir deguonies jutiklį. Remiantis atliktais tyrimais pastebėta, kad naudojant ištraukimo ventiliatorių patalpose nėra dūmų, sumažėja sudegusio kuro pelenų kiekis. Darbo tikslas: ištirti kieto kuro šildymo katilo automatinio valdymo galimybes. Tyrimais nustatyta, kad kamininio ventiliatoriaus darbo trukmė esant skirtingai katilo apkrovai neturi viršyti 15 sekundžių. Malkų įkrova dega 22 valandas esant +10 oC lauko temperatūrai, o kai temperatūra nukrinta iki -30 °C, degimo laikas trumpėja iki 8 valandų naudojant mišrią medieną. Naudojant deguonies jutiklį ir esant lauko temperatūrai apie 0 °C, sutaupoma 7 – 10 % kuro, o pelenų susidarymas sumažėja iki 3 – 5 litrų per savaitę.
In order to use the biofuel more effectively we need to burn it in wood burners more effectively as well by improving burning process. The possibility to additional ventilator usage for smoke composition by adding lambda sensor is analysed in the work. According to performed experiments the usage of smoke ventilator reduces the ash volume. The purpose of this work: to determine the possibilities of automation of solid biofuel boiler. Performed experiments show that the working time of smoke ventilator at different boiler loadings must not exceed 15 seconds. Mixed wood sample burns 22 hours at the outside temperature of +10 oC and just 8 hours when temperature decreases down to -30 °C. By using the boiler control unit, at the outside temperature of around 0 oC, the wood fuel consumption decrease by 7 – 10 % and ash contend decreases to 3 – 5 litres per week from the Pyros 28 boiler.
Internet: https://hdl.handle.net/20.500.12259/114527
Affiliation(s): Žemės ūkio akademija
Vytauto Didžiojo universitetas
Appears in Collections:VDU, ASU ir LEU iki / until 2018

Files in This Item:
Show full item record
Export via OAI-PMH Interface in XML Formats
Export to Other Non-XML Formats


CORE Recommender

Page view(s)

2
checked on Mar 30, 2021

Download(s)

153
checked on Mar 31, 2021

Google ScholarTM

Check


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.